T/C Extension & Compensating Wires

Industrial Cable

Fluoropolymer Wire (UL) |
UL1726 & 1727

Applicable Standard
UL 758, UL 1581
Operating Temperature
-80~260℃
CATALOG
Features
Fluoropolymer (PFA) insulation
Excellent heat resistance maintains insulation integrity in high-temperature environments
Outstanding waterproof performance in humid conditions
High abrasion resistance protects against physical damage
Applications
home appliances, OA equipment, and industrial FA devices
Reliable signal wiring for high-temperature processes in semiconductor and display industries
Stable data transmission in high-temperature, high-pressure environments in aerospace applications
Materials & Construction
Conductor : Nickel, Nickel plated Copper
Insulation : Fluoropolymer(PFA)
Cross-sectional View
Product Conductor Thickness of Insulation
(mm)
Diameter
(mm)
Rating
Size
(AWG)
Sectional Area
(mm²)
Diameter
(mm)
UL1726 #26 0.14 0.49 0.33 1.15 300V
250℃
#24 0.20 0.62 0.33 1.28
#22 0.30 0.75 0.33 1.41
#20 0.50 0.95 0.33 1.61
#18 0.75 1.23 0.33 1.89
#16 1.25 1.54 0.33 2.20
#14 2.00 1.88 0.33 2.54
#12 3.50 2.65 0.33 3.31
#10 5.50 3.29 0.33 3.95
UL1727 #26 0.14 0.49 0.51 1.51 600V
250℃
#24 0.20 0.62 0.51 1.64
#22 0.30 0.75 0.51 1.77
#20 0.50 0.95 0.51 1.97
#18 0.75 1.23 0.51 2.25
#16 1.25 1.54 0.51 2.56
#14 2.00 1.88 0.51 2.90
#12 3.50 2.65 0.51 3.67
#10 5.50 3.29 0.51 4.31
LIST